3G Dual Sim GATEWAY

2N® Easygate Dual Sim is light weight, compact & quick to install. Designed for the lift environment & to connect Australia’s elevators to the digital network, due to the nbn™.

RCM approved

Repsonsible Supplier No. E7158

Self testing & reporting in accordance with EN: 81-28

Land-line & nbn™ replacement

Easy installation external fixing bracket Monitoring by SMS report

Easy battery replacement

Dual Sim Gateway

Item No. 5013681LAU

Installation

3G Dual Sim GATEWAY

Technical Specifications

MACHINE ROOM SHAFT

ANY LIFT

COMMUNICATOR

CABIN

PRO

2N® EASY GATE

4X AA

BATTERIES

(NmHi)

DISPATCHER/SUPERVISOR

SERVICE CAR

Lift1 Emergency Elevator Telephones

Precision communication products for safety of passengers and lift technicians.

Fully powered over phone line/via gateway RCM approved

Lift1

CABIN UNIT COP

COP version - Internal Speaker & Microphone

Item No. 919640AU

COP version - External Speaker & Microphone

Item No. 919640XAU

Lift1

CABIN UNIT SURFACE MOUNT

With button

Item No. 919645AU

Without button

Item No. 919645WBAU

Lift1

CABIN UNIT TOC

With Voice alarm station switch

Item No. 919631AU

Without Voice alarm station switch

Item No. 919630AU

Lift1

CABIN UNIT FLUSH MOUNT

With button

Item No. 919618BAU

Without button

Item No. 919618AU

Lift1

Lift1 VOICE ALARM STATION SET

For top and under cabin

Item No. 913661ESET

Lift1 MACHINE ROOM STATION SET

Machine room unit

Item No. 919654ESET

Lift1 Emergency Telephones

Installation Technical Specifications

PRO

4X AA BATTERIES

(NmHi)

MR PHONE

MACHINE ROOM SHAFT

2N® LIFT1

CABIN

2N® EASY GATE

DISPATCHER/SUPERVISOR

SERVICE CAR

8

Lift8

A highly modular lift communication system, where the two-wire bus makes the Lift8 readily installable in any lift context.

This means that when it comes to installing emergency lift communications for multi lift buildings, new cabling is not required.

2 wire bus in shaft including power Comprehensive, modular, expandable Wide range of communication interfaces

Lift8

CABIN UNIT COP

COP version - fixed

Item No. 918600E

COP version - wired

Item No. 919640XE

Lift8

CABIN UNIT SURACE MOUNT

With button

Item No. 918613E

Without button

Item No. 918613WBE

Lift8

MACHINE ROOM PCB

For MRL elevators

Item No. 918619E

Lift8

CABIN UNIT FLUSH MOUNT

With button

Item No. 918618BE

Without button

Item No. 918613WBE

Lift8

Lift8

MACHINE ROOM UNIT Lift8

SHAFT UNIT Lift8

SHAFT UNIT ANTIVANDAL Lift8 SPLITTER Lift8 I/O MODUL

MR unit + programming

Top, under cabin or pit

For heavy duty environment

Shaft extender

For easy lift monitoring

Item No. 918611E Item No. 918612E Item No. 918617E Item No. 918620E Item No. 918621E

Lift8

Lift8

CAMERA MODULE

For visual alarm confirmation

Item No. 918622E

Lift8 PICTOGRAM CONTROLLER

External pictogram driver

Item No. 918655E

Lift8 VOICE ALARM STATION SET

For top and under cabin

Item No. 913662ESET

Lift8

Lift8

CENTRAL UNIT

Item No. 918600E

Maxi

Item No. 918601E

Communication interface

Monitoring interface

Lift8 PSTN

Item No. 918652E

Lift8 UMTS

Item No. 918651E

Lift8 VOIP

Item No. 918653E

Lift8 RS232

Item No. 918654E

2N®Lift8 IP

Item No. 918655E

Installation Technical Specifications

Lift8

LIFT8

2N® LIFT8

CENTRAL UNIT

ENGINE ROOM

6

/ UMTS/VOIP

LIFT8

Central unit

Power 100 - 240 V; 50/60 Hz; 0.75 A; 60 W max.

Backup power supply Built-in lead acid battery

Connection options 4 reporting units + 7 splitters + 8 I/O modules Maximum distance between the splitters 100 m

Control-room connection interface UMTS / VoIP

Configuration and monitoring Voice menu / USB / remote

SHAFT 1

2

2

/

UP TO 8 WELLS

2N® LIFT8 SPLITER

ENGINE ROOM

SHAFT 8

2

2

/

DISPATCHER/SUPERVISOR

Status indicators 5× LED, three-colour

Dimensions and weight 300×170×72 mm, 2.7 kg

Splitter 10 to 20 V, 25 to 50 Hz

Power 24 V from a central or local unit

Capacity 4 reporting units + camera module

Maximum total shaft cable length 600 m

Lift blocker output Relay, NO and NC contacts

Dimensions 142×98×34 mm

Reporting units 9V AC or DC

Link to splitter 2 wires for power, voice and data

Inputs for buttons and signals ALARM1, ALARM2, CANCEL

LED signalling Connecting, Connection confirmed

CAR

Option to hook up an external microphone, speaker and LED

Yes, on the cabin reporting unit

CAR

Numeric keypad, system configuration option Yes, on the machine room reporting unit

2

/ 2

/

2N® LIFT8 FIREMAN

Option to connect an earpiece in noisy circumstances

Yes, in the machine room and shaft reporting units

2N® LIFT8

SHAFT ANTIVANDAL

In-shaft visibility Yes, backlit buttons

I/O Module 200 mA

Power 24 V from a central or local unit

Capacity 4 inputs + 4 outputs

Inputs Galvanically isolated, 12 - 24 V AC or DC

Outputs Relay, contacts Normally-Open (NO), max. 250 V, 5 A

Dimensions 142×98×34 mm

14

Lift SOFTWARE

Call Centre for Lifts is a software solution for the comprehensive management of emergency lift telephones.

The software will even allow you to handle alarms and control calls. It provides a detailed overview of all your calls from the elevator and the option to archive or export the data e.g. for customer reports.

This software can also be used to receive reports on the status of the line between the Lift 1 elevator emergency phones and the gateway.

Management of control and alarm calls No extra hardware required

Support for CPC and P100 protocols

Line check call capability with Lift 1 Emergency Telephones

CALL CENTRE FOR LIFTS

Item No. 918700E

Lift SOFTWARE

Lift8 SERVICE TOOL Lift1 SERVICE TOOL

The Lift8 Service Tool is software used for local (USB) or remote (IP) configuration of one complete Lift8 communication system (audio messages, additional modules, splitters and I/O modules).

With the aid of Lift1 Service Tool software for Windows Professional, you will be able to completely set up the

Lift1 emergency telephone. In addition, the software application can be used to

configure & install an upgrade.

INDUCTION LOOP FOR LIFTS

Emergency lift communication for the hearing-impaired.

The Induction Loop is an inductive loop that delivers audio to the lift-cabin interior, where it transmits the sound to hearing aids with a built-in inductive sensor.

The induction loop is an indispensable assistant in resolving emergency communications from inside the lift for hearing aid users.

Connect to any lift communicator

Take advantage of two independent audio inputs

Cover the lift space with a signal for the hearing-impaired

INDUCTION LOOP AMPLIFIER WITH ANTENNA

Item No. 919622E

Lift ACCESSORIES Certification

ACMA approved

Responsible Supplier No. E7158 AS/NZS 60950.1.2011 A1:1.2012 AS/CA S002:2010. A1:2012 AS/CA S003.1:2010. A1: 2012 AS/CAQ S004: 2013

AS/CA S042.1: 2015

AS/ACIF S042.3: 2005

AS/CA S042.4: 2015

Authorised 2N Partner

TÜV SÜD Certified

All emergency communication products are certified by TÜV SÜD Czech. The TÜV certifficates confirm compliance with EN81-28, EN 81-70, EN81-72 and EN81-80.

ELEVATOR NORMS

EN 81-28 – Emergency calls. The purpose of this standard is to improve communication in emergency situations in elevators.It eliminates the risk of passengers being entrapped due to malfunctions in elevator installation.This is accomplished by fitting all elevators with an emergency call system. This alarm system must be capable of establishing a

two-way voice communication between people in an elevator cabin and a remote emergency (rescue) service. The EN 81-28 standard thus applies to all new and modernized elevators.

EN 81-70 – Barrier free elevators. EN 81-70 defines the minimum requirements for safe independent access and use of elevators by all passengers, including those with disabilities. It provides guidelines on how to best improve the accessibility on the approach to elevators, within elevator cars and while exiting elevators. This standard allows people with reduced mobility (pushchairs, wheelchairs, walking aids, etc.) or other disabilities (mental disability,

sight and hearing impairment, etc.) to enter elevator cabins easily and operate elevators without limitations.

EN 81-72 deals with the significant hazards, hazardous situations and events relevant to firefighter elevators installed mostly in new buildings. They are primarily intended for use by passengers and thus may be used for firefighting and evacuation purposes

under direct control of firefighters. These elevators can only operate within a protected environment. They are designed with additional protection, controls and signals enabling rescue from inside or outside elevator cars in case of fire.

ELEVATOR NORMS

EN 81-20 replaces the EN 81-1 standard and specifies the emergency call system requirements in greater detail. Lifts must now be equipped with additional communication units. Additional equipment must be installed with the ALARM system under the EN 81-28 standard to allow a person trapped in the shaft to place an emergency call. This must be accessible from locations where the risk of a person being trapped exists.

EN 81-71 – Vandal resistant elevators. The EN 81-71 standard defines the testing methodology and classification of elevators according to their vandal resistance. It entails special protective measures and security rules against acts that may result in damage to elevators or injury to passengers. Furthermore, this standard provides guidance to building designers, customers, etc., and requirements for design in projects requiring additional security in order to protect against the risk of vandalism.

EN 81-80 – Elevator modernization / hazard analysis. EN81-80 SNEL (Safety Norm for Existing Lifts) improves the security of existing passenger and goods passenger elevators. The aim is to match the level of safety achieved by newly installed elevators. This standard defines rules for improving safety of existing

elevators based on risk assessment and categorises various hazards and hazardous situations. It also lists corrective actions that can be implemented to progressively improve safety.

ELEFONE MONITORING PTY LTD

www.elefone.com.au 02 8860 9552

admin@elefone.com.au

Level 5, Nexus Building, 4 Columbia Court,

Norwest, NSW 2153 Australia

Access 2019 Edition 1